Slow ops
Webb15 maj 2024 · 经过几次尝试,发现提示这种情况的slow ops时,需要首先使用systemctl stop [email protected]命令使[email protected]进程停止后,再使用systemctl start [email protected]才不会发生上述问题(执行完systemctl stop 命令后,不要马上重新执行systemctl start,需要等待集群状态趋于稳定后再执行systemctl start命令,可以通 … Webb13 juli 2024 · 错误类似:26 slow ops, oldest one blocked for 48 sec, daemons [osd.15,osd.17,osd.18,osd.5,osd.6,osd.7] have slow ops. 如果只是集群中极少部分的OSD出现该问题,可以通过: systemctl status ceph-osd@{num} 查看OSD日志找到问题并处理,常见的有磁盘故障等,根据错误网络搜索很多解决方案。
Slow ops
Did you know?
Webb17 aug. 2024 · 2. slow ops # ceph -s 21 slow ops, oldest one blocked for 29972 sec, mon.ceph1 has slow ops 先保证所有存储服务器上的时间同步一致,再重启相应主机上的moniter服务解决。 3. pgs not deep-scrubbed in time # ceph -s 47 pgs not deep-scrubbed in time CEPH系统每1~1.5天对所有的PGs进行一致性检验(scrub,通过文件的元数据信息 … Webb12 nov. 2024 · 一个关于Ceph的slow request问题. 刚进公司的第三天,接到一个关于ceph稳定性的攻关任务。. 公司内部集群采用k8s的部署模式,用ceph来做存储模块。. ceph是5node、3monitor的集群。. 同事描述了几个现象,1、mysql访问偶现夯住,服务端直接报错,由于涉及线上业务已切换 ...
Webb31 mars 2024 · Omdat je bij slow cooking een constante temperatuur wilt hebben is onze barbecue-expert enorm fan van de keramische barbecue, zoals bijvoorbeeld de Kamado barbecue. Ook een bbq die op hout stookt, is te gebruiken om low and slow vlees te garen. Vergeet niet dat je ‘m moet afsluiten, dus gebruik er een met ‘n deksel. Webb14 apr. 2024 · “These actions have slowed the start of operations throughout the Southern California port complex,” the PMA said. So far, no severe disruption is visible at the two ports. Access to truck gates were mostly open on Thursday and Friday, according to data from the Port of Los Angeles and Port of Long Beach .
Webbbuild/ops: make patch build dependency explicit (issue#40175, pr#30046, Nathan Cutler) build/ops: python3-cephfs should provide python36-cephfs (pr#30983, Kefu Chai) build/ops: rpm: always build ceph-test package (pr#30049, Nathan Cutler) build/ops: rpm: fdupes in SUSE builds to conform with packaging guidelines (issue#40973, pr#29784, … WebbAn OSD with slow requests is every OSD that is not able to service the I/O operations per second (IOPS) in the queue within the time defined by the osd_op_complaint_time …
WebbIn my script, I have for loop over many cube objects (~1000) and the treatment is very slow. Looking more in details, I notice that in the same amount of loops: if I use python …
WebbMON_DISK_LOW mon master003 is low on available space mon.master003 has 22% avail 并且通过 log 也无法完全定位问题时,可以通过如下方式解决。 删除 osd 重新加载 删除当前的 osd 重新让其进行加载,此方式适合于异常重启后的操作。 首先删除这个 osd: $ ceph osd out osd.0 $ systemctl stop ceph -osd@ 0 $ ceph osd crush remove osd.0 $ ceph … clusters ios appWebb25 juli 2024 · However, they are slowly losing those customers to new SaaS accounting applications, bigger channel players and accounting practices, so unless they can revitalise their new customer sales activities, it will be a slow death by attrition. Race to the bottom. The implications are that traditional accounting software resellers are in for a tough ... clusters in snowflakeWebb1 pools have many more objects per pg than average 或者 1 MDSs report oversized cache 或者 1 MDSs report slow metadata IOs 或者 1 MDSs report slow requests 或者 4 slow ops, oldest one blocked for 295 sec, daemons [osd.0,osd.11,osd.3,osd.6] have slow ops. clusters in sqlWebb29 apr. 2024 · 1 MDSs report slow requests Reduced data availability: 38 pgs inactive Degraded data redundancy: 122006/1192166 objects degraded (10.234%), 102 pgs degraded, 116 pgs undersized 101 slow ops, oldest one blocked for 81045 sec, daemons [osd.1,osd.2] have slow ops. 重启 mon 即可解决: $ systemctl restart ceph-mon.target cabot class starshipWebb19 nov. 2024 · The main causes of OSDs having slow requests are: Problems with the underlying hardware, such as disk drives, hosts, racks, or network switches. Problems … cabot circus to cribbs causewayWebb10 apr. 2024 · Listen to article. The watchdog set up by the federal government to probe corporate wrongdoing abroad is slow, ineffective and has created a process bogged down in bureaucracy, say two of the ... clusters in sql serverWebb11 mars 2024 · 这种问题叫做 SLOW_OPS 。 所以,只要可能失联的 OSD 仍然在 osdmap 里面,那么 leader monitor 就会把针对它的小报告一直保留下来。 直到 leader 收集到足够的证据,或者举报的人主动撤销或者自己出局。 但是也有可能证据一直不够充分,那么 leader 无法做出判断。 而这些报告经 prepare_failure () 处理后,就一直放在 OpTracker 里面,变 … cabot classic yellow mac \u0026 cheese 6.25oz